Modbus sensors

Dependency modules
modbus
Modbus sensors component. You need to know address of device you want to connect to! Supported devices:
| Device | Model name |
|---|---|
| Eastron SDM630 Energy meter | sdm630 |
| Eastron SDM120 Energy meter | sdm120 |
| Sofar Solar PV Inverter | sofar |
Example config
Example config
modbus:
uart: uart1
modbus_sensors:
- id: sofar1
model: sofar
address: 1
- id: sdm1
model: sdm630
address: 32
Configuration variables:
- id (Required, string) - ID to use to name this device in MQTT and Home Assistant
- address (Required, string) - address of the device you want to fetch data for.
- model (Required, string) - model schema to use. Check table above to get model name.
- update_interval (Optional, integer, default: 30 seconds) - update interval in seconds. Modbus connection is pretty cpu intensive so customize with care.